Keeping your sensors aligned properly is extremely important. Poorly aligned sensors are one of the main causes of tracking problems.
Below are the instructions for checking the alignment on Wintriss Sensors.
It is very important that you do a Start Day each time prior to entering either the Align Sensors or the Track program. Start Day is what actually turns the sensors on, no data is sent from the cameras until a Start Day is done.
Step 2 - Double-Click Start Day
All Cameras/Sensors in the range should now be fully lit (bright red). If this is NOT the case, then there is a communication problem somewhere. Refer to the Wintriss Communication Problem Page.
There should now be a flickering graph with a clear beginning and ending that resembles a Heart Monitor at a hospital. If all that appears is a straight line at the bottom of the screen, then the sensor is not seeing ANY portion of the tape. Follow the Red Light Box instructions in the user manual to get the sensor to look at the tape.
Putting your arm through the Sensor Array should create a ‘dip’ in the graph. If you move your arm across the length of the tape and up the wall the ‘dip’ should follow. If the dip does not follow your arm throughout the entire array (the complete distance of the tape), then the sensor is not aligned to that portion of the tape.
Place 1 finger across the full width of the tape (3.5 inches), about halfway up the wall across from the sensor being tested. You should see a dip in the graph. Moving your finger back towards you should make the dip get smaller and smaller until it disappears completely. At the exact moment the dip disappears completely (Or fist appears when you move your finger away from you), look at the very tip of your finger. This is the point in the tape where the sensor is looking at this location.
Follow this same step in 2 more locations:
1) On the floor, about a foot away from the wall, Opposite the Sensor
2) On the floor, Under the Sensor, about a foot away from the wall.
This should give you 3 good points to determine which direction the Sensor is looking.
IMPORTANT!: After each camera is aligned, you MUST exit the program, do a Start Day, and re-enter Align Sensors before trying to align the next camera. Failing to do so may create multiple errors and confusion as to which graph is being displayed.
|
||||||
|